150kW hurtiglader
Cloud Platform Management “SSE Cloud” ladestyringsplattform er tilgjengelig om nødvendig. Støtter OCPP, intelligent overvåking, eksternt vedlikehold og online oppgradering i bakgrunnen.
Valgfri lademodus Bruk av én ladekontakt gir full ladeeffekt – men har også intelligent strømfordeling for lading med to kontakter samtidig.
Input | Input voltage (V) | AC400±10% | |
Max. input current (A) | ≤320 | ||
Input frequency (Hz) | 50/60 | ||
Power factor | >0.99 | ||
Output | DC output voltage (V) | 200-750 | |
Rated output power (kW) | 30, 45, 60, 75, 90, 120, 150 | ||
Output current (A) | 0 - 200 | ||
Stabilized voltage precision (%) | ≤±0.5% | ||
Stabilized current precision (%) | ≤±1 | ||
Module current imbalance (%) | ≤5 | ||
Ripple factor (%) | ≤1 | ||
Efficiency (%) | ≥94 | ||
General | Communication protocol | PLC | |
User interface | Touch screen | ||
Metering | DC watt-hour meter to measure the output power | ||
Communication interface | Ethernet; 3G/4G (optional) | ||
Installation | Integrated ground mounted | ||
Cooling | Forced air cooled | ||
Dimensions (W×D×H, mm) |
789×600×1650 (30-60kW) 789×700×1900(75-150kW) depend on the actual model |
||
Protection level | IP54 (outdoor); IP30 (indoor) | ||
Standards | IEC/EN61851 | ||
Environmental | Operating temperature (℃) | -35 to 50 (normal output); 50 to 75 (derating output) | |
Storage temperature (℃) | -40 to 75 | ||
Humidity (%) | 5 - 95 | ||
Altitude (m) | ≤2000 (full load output) | ||
Environment |
No strong vibration and shock, no strong electromagnetic interference, and induction intensity of external magnetic field ≤0.5mT |
||
Installation vertical obliquity (degree) | ≤5 |
Input |
Input voltage (V) |
AC400±10% |
Max. input current (A) |
≤320 |
|
Input frequency (Hz) |
50/60 |
|
Power factor |
>0.99 |
|
Output |
DC output voltage (V) |
200 - 750 |
Rated output power (kW) |
30, 45, 60, 75, 90, 120, 150 |
|
Output current (A) |
0 - 200 |
|
Stabilized voltage precision (%) |
≤±0.5 |
|
Stabilized current precision (%) |
≤±1 |
|
Module current imbalance (%) |
≤5 |
|
Ripple factor (%) |
≤1 |
|
Efficiency (%) |
≥94 |
|
General |
Communication protocol |
PLC |
User interface |
Touch screen |
|
Metering |
DC watt-hour meter to measure the output power |
|
Communication interface |
Ethernet; 3G/4G (optional) |
|
Installation |
Integrated ground mounted |
|
Cooling |
Forced air cooled |
|
Dimensions (W×D×H, mm) |
789×600×1650 (30-60kW); 789×700×1900 (75-150kW) depend on the actual model |
|
Protection level |
IP54 (outdoor); IP30 (indoor) |
|
Standards |
IEC/EN61851 |
|
Environmental |
Operating temperature (℃) |
-35 to 50 (normal output); 50 to 75 (derating output) |
Storage temperature (℃) |
-40 to 75 |
|
Humidity (%) |
5 - 95 |
|
Altitude (m) |
≤2000 (full load output) |
|
Environment |
No strong vibration and shock, no strong electromagnetic interference, and induction intensity of external magnetic field ≤0.5mT |
|
Installation vertical obliquity (degree) |
≤5 |